Feature
The MR Diagnostics Incubator System nomag ® IC is the solution for a major, long standing unresolved problem: With the incubator system, newborns and premature babies can be examined for the fi rst time after birth by optimal non-invasive diagnostics with magnetic resonance imaging. nomag ® IC provides safe intra-hospital transport from neonatology to radiology as well as an MR-conditional
• Our standard: equipment with neonatal array coils!
• Regulates the climate according to the neonatology incubator
• Integrated neonatal head array coil
Benefit for the user
• Improved work flow
• No preparation of the newborns and premature babies in the MR room
• More accurate diagnostics due to the high imaging quality
• Steady monitoring of the patient´s stability during the scanning process
• Shorter mean imaging in the MR room
• More examinations due to the improved workflow
• Decreased examination time
• Due to shorter procedure reduced staff required
• Improved competitiveness
Benefit for the patient
• Optimizes the thermoregulation during the MR examination
• Less sedation and no general anesthesia necessary
• Same environment as in the NICU incubator
• Minimizes the direct physical contact with the newborn
• Better auditory shielding
• Reduced infection risk
• Decreased examination time
Benefit for the neonatology
• More accurate diagnostic due to the high imaging quality
• More exact diagnosis possible with the MRI than with sonography
• Earlier diagnostic possible due to the safe environment - even of critically ill and unstable newborns
• Due to shorter procedure reduced staff required
Head array
8-Channel
Head Array Coil 1.5 / 3.0T
• 8-channel Array, cylindrical, receive only coil
• High-resolution MR Imaging of the brains of newborns and premature babies with a head circumference of up to approx. 40cm
• Compatible with : Siemens (VB, VC, VD, VE), Philips (> 3.2, > 5.1.7), GE (DV 24/25/26), GE (SV 25.1). Further compatibilities are in progress
• Approved for use inside MR Diagnostics Incubator System nomag ® IC ADVANCE
16-Channel
• Head Array Coil 1.5 / 3.0T
• 16-channel Array, cylindrical, receive only coil
• High-resolution MR brain scans of new and premature born babies up to approx. 3 months with head circumference of approx. 42cm
• Compatible with : Siemens (VD, VE), GE (DV 26). Further compatibilities are in progress
• Perfect for scanning intubated patients
• Improved SNR and image homogeneity: 35% increased SNR compared to 8-channel Array coil (e.g. Siemens Skyra)
• Extended field of view for head and throat scans: 17% enhanced field of view compared to 8-channel Array coil
• Approved for use inside MR Diagnostics Incubator System nomag ® IC ADVANCE
Body array
12-Channel
Body Array Coil 1.5 / 3.0T
• 12-channel Array, consisting of 2 elements, can be used separately or together as appropriate, comprised of: 1. part integrated in patient`s bed (8-channels) 2. part as separate coil (4-channels)
• High-resolution MR Imaging of the body of newborns and premature babies, with a weight of up to approx. 4,500g
• Compatible with : Siemens (VB, VC, VD, VE), Philips (> 3.2, > 5.1.7), GE (DV 24/25/26), GE (SV 25.1). Further compatibilities are in progress
• Approved for use inside MR Diagnostics Incubator System nomag ® IC ADVANCE
Compatible with MRI
• Siemens
• GE
• Philips